Installed a Progressive Dynamics 5100 ATS to replace the stock Parallax that has caused so many people problems. Decided I'd be proactive. Very straightforward process. As I removed the old ATS I was unhappily surprised to find that both the load and neutral wires had never been tightened down in the old ATS. I could easily slip both of them from their slots. Guess I've been lucky not to have an "issue" in the last couple of years. IF you are into preventative maintenance, and you're comfortable with electrical stuff, AND you have an ATS, you might check the security of all those connections.